| Electromagnetic starting device for gas fire extinguishing modules MFZ1-90F | Electromagnetic starting device for gas fire extinguishing modules |
| Pneumatic starter for QQQ 0.8 Mpa gas fire extinguishing modules | Pneumatic actuation device for gas fire extinguishing modules |
| High-pressure hose for pneumatic starting system 0.5 m | High-pressure hose for the pneumatic starting system. Designed to connect all components of the pneumatic starting system. Hose length: 0.5 m. |
| High-pressure hose for pneumatic starting system, 1m | High-pressure hose for the pneumatic starting system. Designed to connect all components of the pneumatic starting system. Hose length: 1 m. |
| Atmospheric valve DG-DQ (inlet/outlet M14X1.5) | Atmospheric valve. P close = 0.17 MPa. Features: Designed to maintain atmospheric pressure in the pneumatic starting system line until start-up. It serves as a safety device for the pneumatic starting system – it prevents false activation of the AUGP when the starting module's ZPU is leaking (used in conjunction with the adapter). |
| Adapter for atmospheric valve | Adapter for atmospheric valve |
| Check valve for the QD-QY pneumatic starting system | It is designed to prevent the starting flow from moving in the opposite direction and is used when combining starting devices when a complex pneumatic starting line circuit is organized in a gas fire extinguishing system, usually in centralized installations. |
| Tee for pneumatic starting system | Used when constructing a complex pneumatic start-up line circuit (branched system). |
| Threaded connector for pneumatic starting system | Used to extend the pneumatic start line |
| Pneumatic starter system tube termination kit | The kit for one side of the tube, the termination device and the copper tube are not included. |
| Pneumatic start system plug | Installed on the pneumatic start device of the last module. |
| Safety valve AX-9A | A relief valve is used in multi-way systems. It is designed to provide emergency pressure relief in the manifold to prevent rupture in the event of a distribution device failure. R 1/2". Installed in the manifold for the MGP. |
| Check valve YD 32H (inlet M48X2, outlet Rc 1 1/4") | The check valve is designed to prevent reverse flow of the flammable liquid and is used when connecting cylinders in a gas fire extinguishing battery. Operating pressure: 20 MPa. Inlet: M48x2, outlet: Rc: 1 1/4". Installed between the manifold and the high-pressure hose of each cylinder. |
| Check valve YD 50H (inlet M68X2, outlet Rc 2") | The check valve is designed to prevent reverse flow of the fire extinguishing agent and is used when connecting gas fire extinguishing battery cylinders. Operating pressure is 20 MPa. Inlet is M68x2, outlet is Rc 2". It is installed between the manifold and the high-pressure hose of each cylinder. |
| Pressure alarm XF-8S | The universal pressure alarm is designed to signal the entry of extinguishing agent into the pipeline of gas fire extinguishing systems when control units or distribution devices are activated. It is designed for 24-hour operation in gas and water fire extinguishing systems. The alarm is intended for indoor use. |
| High-pressure hose RVD RG-32G/450, length 450 mm | The high-pressure angle hose is used to connect the outlet fitting of the MGP shut-off and release device to the manifold, or to the distribution pipeline of a gas fire extinguishing system. The hose length is 450 mm. Please note! The SDU is not included in the price. |
| High-pressure hose RVD RG-50G/450, length 450 mm | |
| High-pressure hose RVD RG-32GZ/650, length 650 mm (with a fitting for SDU) | The high-pressure hose is used to connect the outlet fitting of the MGP shut-off and release device to the manifold or to the distribution pipeline of a gas fire extinguishing system. The hose is 650 mm long. The design includes a fitting for a pressure indicator. Please note: The SDU is not included in the price. |
| High-pressure hose RVD RG-50GZ/650, length 650 mm (with a fitting for SDU) | |
| High-pressure hose HPH-50/450, length 450 mm | The high-pressure angle hose is used to connect the outlet fitting of the MGP shut-off and release device to the manifold, or to the distribution pipeline of a gas fire extinguishing system. The hose length is 450 mm. Please note! The SDU is not included in the price. |
| High-pressure hose HPH-32/450, length 450 mm | |
| High-pressure hose RVD NRN-50S/650, length 650 mm (with a fitting for SDU) | The high-pressure hose is used to connect the outlet fitting of the MGP shut-off and release device to the manifold or to the distribution pipeline of a gas fire extinguishing system. The hose is 650 mm long. The design includes a fitting for a pressure indicator. Please note: The SDU is not included in the price. |
| High-pressure hose RVD NRN-32S/650, length 650 mm (with a fitting for SDU) | |
| Adapter ZPU for pneumatic start R1/4-M14*1.5 | Adapter ZPU for pneumatic start R1/4-M14*1.5 |