Sirius PKV Exd

Sirius PKV Exd
Price on request
Equipment:
  • Request a price from the manager
You choosed:

    Explosion-proof fire alarm control and monitoring device "Sirius PKV Exd"

    The Sirius PKV Exd fire alarm control unit (PPKUP) is designed to monitor and control fire alarm, notification, fire extinguishing, smoke removal systems, and auxiliary engineering and technological equipment involved in ensuring fire safety in hazardous areas.

    Key Features:

    • Built-in module for monitoring the ring line of the DPLS "S2000-KDL-S" for 127 addressable devices;
    • Possibility of installing a second built-in module "C2000-KDL-C";
    • Redundant RS-485 interface for connecting external ISO "Orion" units;
    • Redundant RS-485 interface for connecting up to 32 Sirius control panels into a network with the possibility of cross-control;
    • Built-in redundant power supply;
    • Log for 65000 events;
    • Web interface for configuring parameters, remotely monitoring the system status, viewing, saving and printing the event log;
    • Possibility of connection to the Orion Pro automated workstation to expand the capabilities of monitoring the state of the protected object.

     

    The Sirius PKV Exd fire alarm control system is a modern, flexible, and powerful platform for building fire alarm and automation systems of any complexity. Its key advantages include modularity, integration into the ORION unified security system from Bolid, and the use of advanced analog-addressable technology, ensuring high reliability, information efficiency, and minimal false alarms.

    The Sirius PKV Exd explosion-proof control panel consists of two explosion-proof enclosures. The first enclosure contains the Sirius control panel (control board, power supplies, and switching terminals), while the second contains batteries for backup power for the entire system. The units are connected by flexible cables, with a maximum distance of 0.5 meters between them.

    Ensuring explosion protection and operating conditions

    The explosion-proof fire alarm control and monitoring device "Sirius PKV Exd" belongs to explosion-proof electrical equipment of groups I, II and III according to GOST 31610.0-2019 (IEC 60079-0:2017) and is intended for use in explosive zones of premises and outdoor installations, as well as in mining complexes in accordance with the explosion protection marking according to GOST 31610.0-2019 (IEC 60079-0:2017), GOST IEC 60079-1-2013, GOST IEC 60079-1-2013, GOST 31610.7-2017 (IEC 60079-7:2015), GOST IEC 60079-31-2013:

    • For versions made of aluminum alloy or stainless steel, the control unit and battery unit may have one or a combination of markings from groups II and III (see Table No. 1).
    • The device for mine use is made of stainless steel, the control unit and battery unit may have one or a combination of markings from groups I and III (see table No. 1).

    The device can be used in hazardous areas of classes 1 and 2 according to GOST 31610.10-1-2022 (IEC 60079-10-1:2020) and dust areas in accordance with GOST 31610.10-2-2017/IEC 60079-10-2:2015. The environment may contain explosive mixtures of categories IIA, IIB, IIIA, IIIB, IIIC.

    The explosion-proof Sirius PKV Exd fire alarm control panel is designed for operation at ambient temperatures from 0°C to +40°C and a relative humidity of 80% at 25°C without condensation. The maximum enclosure surface temperature corresponds to temperature class T6. The enclosure protection rating is IP66 according to GOST 14254–2015 (IEC 60529:2013). Climate performance is UHL 4, according to GOST 15150-69.

    The explosion-proof fire alarm control panel "Sirius PKV Exd" is equipped with explosion-proof cable glands of the KV series, according to TU 27.33.13-359-81888935-2019, manufactured by SMD Company LLC. The quantity and type of cable glands are agreed upon when ordering.

    No. Name Material

    Explosion protection marking

    for group I

    for group II

    for group III

    1 Sirius PKV Exd A Aluminum alloy
    AK7h, AK9h

    Control unit:

    PP Ex dc I Mс X

    Battery block:

    PP Ex ec I Mс X

    Control unit:

    1Ex db IIB T6 Gb X

    Battery block:

    1Ex eb IIB T6 Gb X

    Control unit and battery unit:

    Ex tb IIIC T85°C Db X

    2 Sirius PKV Exd H Stainless steel
    AISI304, 12Х18Н10Т

     

    Parameter name Parameter value

    Maximum information capacity of one Sirius PKV Exd device:

    Devices: built-in 4
    external 122
    Inputs (controlled elements) 4096
    Outputs (controlled elements) 1024
    Number of fire extinguishing zones (directions):
    One Sirius device 4
    With "S2000-PT" blocks up to 127
    Built-in communication lines for connecting addressable devices:
    Interface DPLS
    Number of lines 1 (2 – with additional module "S2000-KDL-S")
    Maximum number of AU 127 (254 with additional module "S2000-KDL-S")
    Maximum output current 100 mA
    Nominal output current 64 mA
    Redundant communication line for connecting external units of the ISO "Orion":
    Interface RS-485
    Maximum number of connected blocks 122
    Redundant communication line for connecting Sirius devices into a network:
    Interface RS-485
    Maximum number of Sirius devices in the network 32
    Built-in controlled discrete outputs:
    Key (transistor) outputs: 4 pcs.
    • open and short circuit monitoring
    Yes
    • rated output voltage
    24 V
    • maximum output current
    2 A
    • protection against short circuits and overloads
    Yes
    Dry contact outputs: 3 pcs.: "Fire", "Start", "Malfunction"
    • maximum switching current
    100 mA
    • maximum switching voltage
    200 V
    Output for powering external devices: 1 pc.
    • output voltage
    24 V
    Built-in discrete inputs:
    Input "Fault" 1 pc.
    • open and short circuit monitoring
    Yes
    • rated output voltage
    24 V
    Power supply:
    Basic nutrition AC power supply 220V, 50-60Hz
    Current consumption of the main source own, no more than 0.03A
    battery charge, no more than 0.13A
    Backup power supply two 12 V batteries with a capacity of 17 A∙h
    Current consumption from the backup power source own, no more than 0.3A
    IU, no more than 3A
    Other:
    Technical readiness time 30 sec
    Opening hours 24/7
    Average service life of the device 10 years
    Distance between control unit and battery unit, no more than 0.5 m
    Overall dimensions:
    Made of aluminum alloy
    • Control unit, mm
    • Battery block, mm
    575 x 395 x 278
    575 x 395 x 278
    Stainless steel execution
    • Control unit, mm
    • Battery block, mm
    575 x 395 x 274
    575 x 395 x 265

    Ordering designation:

    Sirius PKV Exd X1
    1 2

     

    1 – name of the device;
    2 – designation of the case material: “A” – aluminum alloy; “H” – stainless steel.

    The type and quantity of cable entries, explosion protection marking are indicated in brackets on the invoice.
    Designation examples: Sirius PCV Exd A ; Sirius PCV Exd H.