445009, Samara region, mountains. Tolyatti st.
Novozavodskaya 2a, building 309

EXPLOSION-PROOF PLUGS

EXPLOSION-PROOF PLUGS
Price on request
Equipment:
  • Request a price from the manager
You choosed:

    Explosion-proof plugs

    Designation Thread, DxP, L turnkey size S, mm
    KV M20 Z M20x1.5, 15mm 27
    KV M25 Z M25x1.5, 15mm 36
    KV M32 Z M32x1.5, 15mm 41
    KV M40 Z M40x1.5, 15mm 50
    KV M50 Z M50x1.5, 15mm 55
    KV M63 Z M63x1.5, 15mm 70
    KV M75 Z M75x1.5, 15mm 80
    KV M90 Z M90x1.5, 15mm 110
         
    SW NPT1/2 Z NPT1/2, 15mm 27
    HF NPT3/4 Z NPT3/4, 15mm 36
    SW NPT1 Z NPT1, 15mm 41
    KV NPT11/4 Z NPT11/4, 15mm 50
    KV NPT11/2 Z NPT11/2, 15mm 55
    HF NPT2 Z NPT2, 15mm 70
    KV NPT21/2 Z NPT21/2, 15mm 80
    KV NPT31/2 Z NPT31/2, 15mm 110

    Plugs are designed to close unused openings in both piping systems and enclosures.

    An example of an entry when ordering and in the documentation: KV (1) M25 (2) Z (3) - L (4)

    1 - Series designation;
    2 - Designation of the attached thread (M25 - M25x1.5);
    3 - Type designation (З - plug);
    4 - Body material (L - nickel-plated brass; H - stainless steel).

    Cable glands of the KV series combine four types of explosion protection and are marked with explosion protection:

    "1Ex d IIC Gb / 1Ex e IIC Gb / Ex tb IIIC Db / PB Ex d I Mb"

    Ex components:

    "Ex d IIC U / Ex e IIC U / Ex tb IIIC U / PB Ex d I Mb U"

    The products of the KV series listed above are produced in versions that differ in: size and type of connecting thread; housing material, cable glands additionally by the type of attached cable.

    Cable glands, can be used in hazardous areas of class 1 and 2 in accordance with GOST IEC 60079-10-1-2011 and in accordance with the explosion protection marking. The environment may contain explosive mixtures of gases and vapors with air of categories IIA, IIB, IIC, and are also electrical equipment of group III, intended for use in places hazardous for explosive dust environments, subgroup IIIC (conductive dust), IIIB (non-conductive dust) and IIIA (flammable volatile particles) and complies with GOST IEC 60079-31-2013.

    Type of explosion protection 1Ex d IIC Gb / 1Ex e IIC Gb / Ex tb IIIC Db/ PB Ex d I Mb
    Operating conditions according to GOST 15150-69 UHL1
    Material: nickel-plated brass stainless steel
    Operating temperature: -60°С<Ta<+135°С
    Thread type: metric (M) pipe conical (NPT).

    All cable glands can be equipped with protective covers (sheaths)

    An example of an entry when ordering and in the documentation: KV (1) M32 (2) B2TV1 (3) - L (4)

    1 - Series designation;
    2 - Designation of the attached thread (M32 - M32x1.5);
    3 - Designation of the type of entry (Б2ТВхх - for an armored cable with a double seal in a pipe with an internal thread;
    4 - Body material (L - nickel-plated brass; H - stainless steel).