Explosion protection marking | 1Ex d IIB T6 Gb |
Ingress protection | IP67 |
Operating temperature range | -60°C…+50°C |
Detecting range, max | 100 m |
Transmitter beam angle | 2° |
Warm-up time after powering up | 30 s |
Velocity of the detectable object, max. | 10 m/s |
'ALARM' notification duration | 2 s |
Operating voltage | 8-28 V |
Input current at operating voltage 12V | |
transmitter (without/with heating) | 15 mA / 30 mA |
receiver (without/with heating) | 10 mA / 25 mA |
Output optical relay characteristics | |
standby mode | Closed |
'ALARM' mode | Open |
Switching current, max | 100 mA |
Switching voltage, max. | 100 V |
Open relay resistance, min | 10 MOhm |
Closed relay resistance, max | 30 Ohm |
input/output galvanic isolation voltage | 1500 V |
Enclosure material | aluminium alloy, stainless steel |
Overall dimensions | |
receiver unit, transmitter unit | 220х210х82mm |
switching units without cable glands | 136х136х80mm |
Features:
Transmitter and receiver units are manufactured with permanently attached cable. Switching boxes for connection of TU and RU, remote junction boxes are included in the delivery package. Junction boxes are supplied with cable glands of various versions:
Cable glands have G1/2 connection thread. Junction box can accept round cable with diameter 6-12 mm.
_______________________________________
Example of order information:
IO209 Mirax-L2 MK - | А | - Т-1/2 |
1 | 2 | 3 |
1 – device type IO209 Mirax-L2 MK: two-component beam detector;
2 – Enclosure material: А – aluminium alloy; Н – stainless steel;
3 – type cable glands:
К – for surface routing of cable;
B – for armoured cable;
Т-1/2 – for routing the cable in pipe with G1/2 thread;
Т-3/4 – for routing the cable in pipe with G3/4 thread;
КМ15 – for cable in metal hose RZTsH-15 mm;
КМ20 – for cable in metal hose RZTsH-20 mm.