ИЗВЕЩАТЕЛЬ ЛИНЕЙНЫЙ ИП212 ТРИОН-Л2 МК <br> 1EXDIIBT6GBX
ИЗВЕЩАТЕЛЬ ЛИНЕЙНЫЙ ИП212 ТРИОН-Л2 МК <br> 1EXDIIBT6GBX ИЗВЕЩАТЕЛЬ ЛИНЕЙНЫЙ ИП212 ТРИОН-Л2 МК <br> 1EXDIIBT6GBX ИЗВЕЩАТЕЛЬ ЛИНЕЙНЫЙ ИП212 ТРИОН-Л2 МК <br> 1EXDIIBT6GBX ИЗВЕЩАТЕЛЬ ЛИНЕЙНЫЙ ИП212 ТРИОН-Л2 МК <br> 1EXDIIBT6GBX ИЗВЕЩАТЕЛЬ ЛИНЕЙНЫЙ ИП212 ТРИОН-Л2 МК <br> 1EXDIIBT6GBX
DETECTOR LINEAR IP212 TRION-L2 MK
1EXDIIBT6GBX
Price from: 754 USD
Housing material
  • A - aluminium alloy
  • N - steinless steel
You choosed:
  • Housing material

  • Address label

  • Cable gland

Linear fire smoke detector IP212 Trion-L2 MK (detector) is designed to detect combustion products (smoke) in fire protection systems of explosive objects and generate a "Fire" signal.

IP212 Trion-L2 MK by the principle of operation is a threshold linear two-position optical-electronic smoke detector.Installed in large rooms with high ceilings.Recommended for use in unheated rooms.

Explosion protection marking 1Ex d IIB T6 Gb
Sheath protection degree IP67
Ambient operating temperature range -40C <Ta <+ 50C
Working range 8-70 m
Controlled area Up to 900 m 2
Supply voltage 8-28V
Consumption current at supply voltage 12V:
emitter unit (unheated / heated) 6 mA / 20 mA
receiver unit (unheated / heated) 20 mA / 40 mA
Ready time after switching on, no more 15 sec
Parameters of the optocoupler relays "Fire", "Fault":
switching current, no more 100 mA
switching voltage, no more 100 V
private key resistance, not less 15 mΩ
public key resistance, no more 16 ohm
galvanic isolation voltage, not less 1500 V
Body material Aluminum alloy, Stainless steel
Dimensions:
receiver unit, emitter unit 356x200x100 mm
switching units without inputs D150x69.5 mm

AM - indicates the presence of a modification of the product with an address label.

Peculiarities:

  • compensation of dustiness of optics;
  • adjustable threshold;
  • optocouplers "malfunction" and "fire";
  • heating of the optical system with the possibility of switching off.


The detector consists of an infrared emitter and receiver.The emitter and receiver are produced with a permanently attached cable, which is connected to the appropriate switching unit.Relay contacts "Fire" and "Fault" are galvanically isolated from each other and from the power line.The detectors are connected by short circuit (in parallel) to the alarm loop.Receiver connection method: four-wire with separate power line.

The detector is supplied with cable glands of various designs:

  • for open cable laying (index in the designation - K );
  • for laying the attached cable in the G1 / 2 ( T-1/2 ) pipe;
  • for laying the attached cable in the G3 / 4 ( T-3/4 ) pipe;
  • for connecting armored cable with an outer diameter of up to 18mm ( B);
  • for connecting a cable in a metal hose RZTsKh-15mm or 20mm ( KM15, KM20).


Connecting thread of cable glands G1 / 2.A round cable with a diameter of 8-12mm can be inserted into the junction box.
______________________________________________
An example of a detector designation when ordering:

IP212 Trion-L2 MK - T-1/2