Products

			КАБЕЛЬНЫЕ ВВОДЫ ДЛЯ ПРОКЛАДКИ КАБЕЛЯ В ТРУБЕ С ВНУТРЕННЕЙ РЕЗЬБОЙ
КАБЕЛЬНЫЕ ВВОДЫ ДЛЯ ПРОКЛАДКИ КАБЕЛЯ В ТРУБЕ С ВНУТРЕННЕЙ РЕЗЬБОЙ КАБЕЛЬНЫЕ ВВОДЫ ДЛЯ ПРОКЛАДКИ КАБЕЛЯ В ТРУБЕ С ВНУТРЕННЕЙ РЕЗЬБОЙ КАБЕЛЬНЫЕ ВВОДЫ ДЛЯ ПРОКЛАДКИ КАБЕЛЯ В ТРУБЕ С ВНУТРЕННЕЙ РЕЗЬБОЙ

Cable glands of the KV series are explosion-proof equipment that meets the requirements of the EU Directive 2014/34/EU, the general requirements of EN 60079-0:2018 and have an explosion protection type "d" according to EN 60079-1:2014, "e" type according to 60079-7 :2015 and type "t" according to 60079-31:2014 and are intended for the introduction of flexible cables into explosion-proof electrical equipment. Cable glands can be used with armored (tape or wire armor) and unarmoured electric and/or fiber optic cables of round and/or flat cross section, as well as cables laid in a metal conduit or pipe. Cable glands securely fix the cable, providing reliable protection of the cable laid in the equipment case from the aggressive environment of the equipment.

Explosion-proof cable glands differ in design, material, size, purpose and type of connecting thread.

Cable glands refer to electrical equipment of group I, II according to the EU Directive 2014/34/EU category M 2 (mine version), 2 G (gas environment), 2 D (field environment). Cable glands may be placed in zones 2, 3, 21 and 22. Explosive mixtures of air with gases and vapors IIA, IIB, IIC, IIIA (flammable flying particles), IIIB (non-conductive dust), IIIC (conductive dust) may be present in the environment .

Cable glands are made of the following materials: group I - stainless steel, group II and III - stainless steel or nickel-plated brass.

 

Application areaNameHousing materialMarking
For groups II and III


Cable
KV series bushings

stainless steel and nickel-plated brassEU directive mark II 2 GD Ex db IIC Gb
Ex eb IIC Gb
Ex tb IIIC Db
For groups Istainless steelEU directive mark IM 2 Ex db I Mb
Type of explosion protection 1Ex d IIC Gb / 1Ex e IIC Gb / Ex tb IIIC Db/ PB Ex d I Mb
Operating conditions according to GOST 15150-69 UHL1

Material:

nickel plated brass

stainless steel

Operating temperature: -60С<Ta<+135С
Thread type:

metric (M)

pipe conical (NPT).

All cable glands can be equipped with protective covers (sheaths)

An example of an entry when ordering and in the documentation: KV (1) M75 (2) TV21 / 2 (3) - L (4)

1 - Series designation;

2 - Designation of the attached thread (M75 - M75x1.5);

3 - Designation of the type of entry (ТВ21/2 - for unarmored cable for pipe connection, internal thread of the entry G2 ½);

4 - Body material (L - nickel-plated brass; H - stainless steel ).

Contacts

  • SMD Company LLC
  • 445009, Samarskay obl.,
  • Togliatty,
  • st. Novozavodskaya 2a, build. 309
  • Аккредитация URS ISO 9001
Write to us, we are online!