The detector is designed to detect fires accompanied by the appearance of smoke or combustion products of low concentration in closed rooms of various buildings and structures, and to send a "Fire" notification to the control panel. The detector can be installed in hazardous areas of premises and outdoor installations of class 0 and lower, depending on the version.

Overview of the TRION VZ detector

Overview of the TRION MK detector

NameIP 212-116.2 Trion MKIP 212-116 Trion VZ
Explosion protection marking1Ex d ia IIB T6 Gb0Ex ia IIB T6 Ga
I.S. parameter labeling LI: 10uH, CI: 1000pF,
Ui: 30V, Ii: 20mA, PI: 0.3W
Degree of protection of the shellIP67/IP31IP67/IP31
Operating temperature range-40°С .. +75°С-40°С .. +75°С
Supply voltage range10V .. 30V10V .. 30V
Consumption current:  
in standby mode, no more90uA90uA
in alarm mode, no more20mA100mA
Detector sensitivity0.05 dB/m .. 0.2 dB/m0.05 dB/m .. 0.2 dB/m
Detector response time, no more5 sec.5 sec.
Housing material

Aluminium alloy,
Stainless steel

High impact polyamide

Selection table for additional resistors

FACP typeConnection options
Parallel connection (make)Sequential connection (on opening)
LB-07Rd must ensure current consumption> 15 mA,Rd \u003d 11 kOhm, Rok \u003d 2 kOhm, VDok \u003d KD522.
Rok \u003d 2 kOhm, VDok \u003d KD522.
RayRd = 2.4 kOhm, Rok = 2.4 kOhm, VDok = KD521A.Rd = 2.2 kOhm, Rok = 2.4 kOhm, VDok = KD521A.
PPK-2Rd = 1.2 kOhm, Rok = 3.6 kOhm, VDok = KD521A.Rd = 10.0 kOhm, Rok = 3.6 kOhm, VDok = KD521A.
fireballRd \u003d 1.5 kOhm (3.0 kOhm - to determine double drawdown),Rd \u003d 8.2 kOhm (4.7 kOhm - to determine double drawdown),
Rok \u003d 4.7 kOhm, do not install VDokRok \u003d 4.7 kOhm, do not install VDok
Yakhont-16iRd \u003d 1.8 kOhm (4.0 kOhm - to determine double drawdown),Not applicable
Rok = 8.2 kOhm, do not set VDok
WERSRd \u003d 820 Ohm (1.8 kOhm - to determine double drawdown),Rd \u003d 10 kOhm (4.7 kOhm - to determine double drawdown),
Rok = 7.5 kOhm, do not set VDokRok = 7.5 kOhm. Do not install VDoc

AM - indicates the presence of a product modification with an address label.

  • IP 212 Trion is a maximum action detector and can be used in short circuit alarm loops (parallel connection). Alarm notification "Fire" is provided by an abrupt decrease in the resistance of the detector.
  • The announcer has the built-in optical indication of operation.
  • A replaceable current-limiting resistor is used to adjust to the control panel type. The detector triggering signal is stored after the end of exposure to combustion products. The detector is returned to the standby mode from the control panel.
  • The detector IP 212 Trion VZ is supplied with two cable glands, which allow the detector to be installed in an alarm loop with a round cable with a diameter of 6-10 mm
  • The detector IP 212 Trion MK is supplied with cable glands of various designs:
    • for open laying of the attached cable with a diameter of 6-12 mm (index in the designation - K );
    • for laying the attached cable in the pipe G1/2 ( ТG-1/2 );
    • for laying the attached cable in the pipe G3/4 ( ТG-3/4 );
    • for connecting an armored cable with a diameter of 6-12mm ( B).