Products

ПОСТЫ УПРАВЛЕНИЯ СЕРИИ ПКВ МК Exe-Н

Explosion-proof control stations, models PKV MK Exe-N-101009 / 101609 / 121209 / 123609 / 161611 / 162111 / 122211 / 181811 / 162611 / 163612 / 232012 / 232020 / 232812 / 23 302

, PKV MK Exi-N-101009 / 101609 / 121209 / 123609 / 161611 / 162111 / 122211 / 181811 / 162611 / 163612 / 232012 / 232020 / 232812 / 233320 / 40312 / 40312

are intended for switching, control and indication of operating modes of electric circuits of alternating and direct current of industrial frequency in explosive zones, as well as for connecting armored and unarmored electric cables of round or flat cross section in a metal hose or pipe.

The material used for the manufacture of control posts is stainless steel.

Control stations are provided with the following types of explosion protection: GOST R IEC 60079-7-2012 Increased protection type "e", GOST 31610.11-2014 (IEC 60079-11:2011) "intrinsically safe electrical circuit "i", GOST IEC 60079-1-2013 " flameproof enclosures "d"" and GOST IEC 60079-31-2013 equipment with dust ignition protection enclosures "t".

The equipment belongs to electrical equipment of groups I, II and III according to GOST 31610.0-2014 and is intended for use in explosive areas of premises and outdoor installations in accordance with the explosion protection marking. The equipment can be used in explosive zones of class 0, 1 and 2 according to GOST IEC 60079-10-1-2011, as well as in mines and mines GOST 31439-2011 (EN 1710:2005). The environment may contain explosive mixtures of gases and vapors with air of category IIA, IIB, IIC, dust IIIC.

As standard, the customer chooses: the type of cable glands, their number, as well as switching elements, indications, text inscriptions. Depending on the available space inside the housing, terminal clamps of two types are installed, screw or spring. Each switching element has one or two contacts. Normally closed and normally open contacts can be used. The manufacturer reserves the right to arrange all elements according to his project.

Posts can have signs with operational inscriptions in Russian and foreign languages: “Start”, “Stop”, “Forward”, “Back”, “Up”, “Down”, “Right”, “Left”, “Quickly”, “ Slow”, “Jog”, “Brake”, “Open”, “Closed”, “Off”, “Aut-0-On” and other short inscriptions on customer request.

Series control posts - PKV,
model range: PKV MK Exe-N-ХХХ… Х, PKV MK Exi-Н-ХХХ… Х.
Explosion protection marking
Housing materialStainless steel
The degree of protection of the shell in accordance with GOST 14254-2015IP66
Ambient temperature in operationT6 from -60°C to +80°C
T5 from -60C to +95°C
T4 from -60°C to +130°C
Temperature class according to GOST 31610.0-2014.T6, T5, T4
Climatic performanceHL (F), UHL (NF), OM (MU)
Switched current, A
- alternating current
- direct current

no more than 200
no more than 200
Switched voltage, V
- alternating current
- direct current

no more than 1000
no more than 1000
ModelOverall dimensions without cable
inputs and external components
Installation dimensionsHull weight, no more
PKV MK Exe/Exi-N-101009100x100x91 mm65x121 mm 
PKV MK Exe/Exi-N-101609100x160x91 mm121x125 mm 
PKV MK Exe/Exi-N-121209120x122x91 mm141x87 mm 
PKV MK Exe/Exi-N-123609120x360x91 mm141х325 mm 
PKV MK Exe/Exi-N-161611160x160x110 mm125x181 mm 
PKV MK Exe/Exi-N-162111160x210x110 mm181x175 mm 
PKV MK Exe/Exi-N-122211120x220x110 mm141x185 mm 
PKV MK Exe/Exi-N-181811180x180x110 mm145x201 mm 
PKV MK Exe/Exi-N-162611160x260x110 mm181x225 mm 
PKV MK Exe/Exi-N-163612160x360x120 mm181х325 mm 
PKV MK Exe/Exi-N-232012230x200x120 mm195x221 mm 
PKV MK Exe/Exi-N-232020230x200x200 mm195x221 mm 
PKV MK Exe/Exi-N-232812230x280x120 mm251x245 mm 
PKV MK Exe/Exi-N-233320230x330x200 mm251x295 mm 
PKV MK Exe/Exi-N-403112403x313x120 mm368x334 mm 
PKV MK Exe/Exi-N-403120403x313x200 mm368x334 mm 

Order entry example:

PKV MK Exe-N-121209B [x1]– D [x2]S[ s1c1–k1–m1, s2c2–k2–m2, s3c3–k3–m3 ]
123
  • 1 - type of control post and type of explosion protection: PKV MK Exe-N-xxxxxx, PKV MK Exi-N-xxxxxx ;
  • 2 - type of cable glands:
    B, D - short sides of the post;
    n is the multiplier of the number of inputs of the corresponding type, if one is not indicated;
    x1, x2, x3, x4 – types of cable glands, for example:
    KV M20K - for open cable laying with connecting thread M20x1.5;
    KV M20KM15 - for metal hose 15mm with connecting thread M20x1.5;
  • 3 – control elements description area:
    S – marker of the control elements description section;
    s1, s2, s3 control designation;
    c - color (only for lamps and buttons K10, K11):
    k - red; h - green; g - yellow; h - black;
    k – type of contacts (only for buttons and switches):
    NONO, NOZ, NZNZ, NZ, BUT;
    m - operational inscription (nameplate).

Contacts

  • SMD Company LLC
  • 445009, Samarskay obl.,
  • Togliatty,
  • st. Novozavodskaya 2a, build. 309
  • Аккредитация URS ISO 9001
Write to us, we are online!