ПОСТЫ УПРАВЛЕНИЯ СЕРИИ ПКВ МК Exe-П
ПКВ МК Exe-П ПКВ МК Exe-П

Explosion-proof control posts, models of the PKV MK EXE-P-080706 /110807 /130707 /180807 /250807 /090904 /101004 /101009 /122209 /161609 /162609 /163609 /252512 /254012 /404012 /4012 /4012 /4012 /4012 /4012 /4012 /4012 /40 -080706 / 110807 /130707 /180807 /250807 /090904 /101004 /101009 /121209 /122209 /161609 /162609 /163609 /211209 /252512 /254012 /404012 are intended for switching, controlling and indicting the operating circuits frequencies in hazardous areas, as well as for connecting armored and unarmored electric cables of round or flat cross section in a metal hose or pipe.

The material used for the manufacture of control posts is polyamide.

Control stations are provided with the following types of explosion protection: GOST R IEC 60079-7-2012 Increased protection type "e", GOST 31610.11-2014 (IEC 60079-11:2011) "intrinsically safe electrical circuit "i", GOST IEC 60079-1-2013 " flameproof enclosures "d"" and GOST IEC 60079-31-2013 equipment with dust ignition protection enclosures "t".

The equipment belongs to electrical equipment of groups I, II and III according to GOST 31610.0-2014 and is intended for use in explosive areas of premises and outdoor installations in accordance with the explosion protection marking. The equipment can be used in explosive zones of class 0, 1 and 2 according to GOST IEC 60079-10-1-2011, as well as in mines and mines GOST 31439-2011 (EN 1710:2005). The environment may contain explosive mixtures of gases and vapors with air of category IIA, IIB, IIC, dust IIIC.

As standard, the customer chooses: the type of cable glands, their number, as well as switching elements, indications, text inscriptions. Depending on the available space inside the housing, terminal clamps of two types are installed, screw or spring. Each switching element has one or two contacts. Normally closed and normally open contacts can be used. The manufacturer reserves the right to arrange all elements according to his project.

Posts can have signs with operational inscriptions in Russian and foreign languages: “Start”, “Stop”, “Forward”, “Back”, “Up”, “Down”, “Right”, “Left”, “Quickly”, “ Slow”, “Jog”, “Brake”, “Open”, “Closed”, “Off”, “Aut-0-On” and other short inscriptions on customer request.

 

Series control posts - PKV,
model range: PKV MK Exi-P-XXX… X, PKV MK Exi-P-XXX… X.
Explosion protection marking RO Ex ia I Ma X / 0Ex ia IIC T6… T5 Ga X / Ex tb IIIC T80 0 C… T95 0 C Db X
RP Ex eb db I Mc X / 1Ex eb db IIC T6… T5 Gb X / Ex tb IIIC T80 0 C… T95 0 C Db X
Housing materialpolyamide
The degree of protection of the shell in accordance with GOST 14254-2015IP66
Ambient temperature in operationT6 - from -60 0 C to +80 0 C
T5 - from -60 0 C to +95 0 C
Temperature class according to GOST 31610.0-2014.T6, T5
Climatic performanceHL (F), UHL (NF), OM (MU)
Switched current, A
- alternating current
- direct current

no more than 200
no more than 200
Switched voltage, V
- alternating current
- direct current

no more than 1000
no more than 1000
ModelOverall dimensions without cable
inputs and external components
Installation dimensionsHull weight, no more
PKV MK Exe/Exi-P-08070680x75x55 mm68x45 mm 
PKV MK Exe/Exi-P-110807110x80x70 mm60x92 mm 
PKV MK Exe/Exi-P-130707130x80x70 mm62x112 mm 
PKV MK Exe/Exi-P-180807180x80x70 mm62x162 mm 
PKV MK Exe/Exi-P-250807250x80x70 mm62x232 mm 
PKV MK Exe/Exi-P-09090490x90x40 mm86x66 mm 
PKV MK Exe/Exi-P-101004100x100x43 mm- 
PKV MK Exe/Exi-P-101009100x100x91mm- 
PKV MK Exe/Exi-P-121209120x120x91mm82x106 mm 
PKV MK Exe/Exi-P-122209120x220x91 mm82x204 mm 
PKV MK Exe/Exi-P-161609160x160x91 mm110x140 mm 
PKV MK Exe/Exi-P-162609160x260x91 mm110x240 mm 
PKV MK Exe/Exi-P-163609160x360x91mm110x340 mm 
PKV MK Exe/Exi-P-211209210x120x9 mm98x175 mm 
PKV MK Exe/Exi-P-252512250x255x121mm200x235 mm 
PKV MK Exe/Exi-P-254012250x400x121mm200x380 mm 
PKV MK Exe/Exi-P-404012400x400x121mm351х380 mm 

Order entry example:

PKV MK Exe-P-121209B [x1]– D [x2]S[ s1c1–k1–m1, s2c2–k2–m2, s3c3–k3–m3 ]
123
  • 1 - type of control post and type of explosion protection: PKV MK Exe-P-xxxxxx, PKV MK Exi-P-xxxxxx ;
  • 2 - type of cable glands:
    B, D - short sides of the post;
    n is the multiplier of the number of inputs of the corresponding type, if one is not indicated;
    x1, x2, x3, x4 - types of cable glands, for example:
    KV M20K - for open cable laying with connecting thread M20x1.5;
    KV M20KM15 - for metal hose 15mm with connecting thread M20x1.5;
  • 3 – control elements description area:
    S – marker of the control elements description section;
    s1, s2, s3 control designation;
    c - color (only for lamps and buttons K10, K11):
    k - red; h - green; g - yellow; h - black;
    k – type of contacts (only for buttons and switches):
    NONO, NOZ, NZNZ, NZ, BUT;
    m - operational inscription (nameplate).