Ready-made solutions Explosion-proof starters designed for local and remote control of electric motors in AC networks of electrical installations in the chemical, gas, oil and other industries.The starters can be used in explosive zones of class 1 and 2 according to GOST IEC 60079-10-1-2011 and have the explosion protection marking "1Ex d IIC T6 ... T3 Gb X (except for acetylene) / Ex tb IIIC T85 ° C ... T200 ° C Db, Climatic version UHL2.
Depending on the selected model, the Starter kit includes starters, thermal relays manufactured by Schneider Electric, with control elements and cable glands, in an explosion-proof shell PKV MK.
PKV MK 302021 Exd-STARTER-M-9 Explosion-proof starter - 9 A without thermal relay, local control, 2 cable glands KV M20B-L for armored cable with a diameter of 12.50-20.90 mm |
|
PKV MK 302021 Exd-STARTER-D-9 Explosion-proof starter - 9 A without thermal relay, remote control, 3 cable entries KV M20B-L for armored cable with a diameter of 12.50-20.90 mm |
|
PKV MK 302021 Exd-STARTER-M-9T Explosion-proof starter - 9 A with a thermal relay, local control, 2 cable glands KV M20B-L for armored cable with a diameter of 12.50-20.90 mm |
|
PKV MK 302021 Exd-STARTER-D-9T Explosion-proof starter - 9 A with a thermal relay, remote control, 3 cable glands KV M20B-L for armored cable with a diameter of 12.50-20.90 mm |
|
PKV MK 302021 Exd-STARTER-M-9R Explosion-proof starter - 9 A without thermal relay, reverse, local control, 2 cable glands KV M20B-L for armored cable with a diameter of 12.50-20.90 mm |
|
PKV MK 302021 Exd-STARTER-D-9R Explosion-proof starter - 9 A without thermal relay, reverse, remote control, 3 cable glands KV M20B-L for armored cable with a diameter of 12.50-20.90 mm |
|
PKV MK 362821 Exd-STARTER-M-9RT Explosion-proof starter - 9 A with a thermal relay, reverse, local control, 2 cable glands KV M20B-L for armored cable with a diameter of 12.50-20.90 mm |
|
PKV MK 362821 Exd-STARTER-D-9RT Explosion-proof starter - 9 A with a thermal relay, reverse, remote control, 3 cable glands KV M20B-L for armored cable with a diameter of 12.50-20.90 mm |
|
PKV MK 302021 Exd-STARTER-M-12 Explosion-proof starter - 12 A without thermal relay, local control, 2 cable glands KV M20B-L for armored cable with a diameter of 12.50-20.90 mm |
|
PKV MK 302021 Exd-STARTER-D-12 Explosion-proof starter - 12 A without thermal relay, remote control, 3 cable glands KV M20B-L for armored cable with a diameter of 12.50-20.90 mm |
|
PKV MK 302021 Exd-STARTER-M-12T Explosion-proof starter - 12 A with a thermal relay, local control, 2 cable glands KV M20B-L for armored cable with a diameter of 12.50-20.90 mm |
|
PKV MK 302021 Exd-STARTER-D-12T Explosion-proof starter - 12 A with a thermal relay, remote control, 3 cable glands KV M20B-L for armored cable with a diameter of 12.50-20.90 mm |
|
PKV MK 302021 Exd-STARTER-M-12R Explosion-proof starter - 12 A without thermal relay, reverse, local control, 2 cable glands KV M20B-L for armored cable with a diameter of 12.50-20.90 mm |
|
PKV MK 302021 Exd-STARTER-D-12R Explosion-proof starter - 12 A without thermal relay, reverse, remote control, 3 cable glands KV M20B-L for armored cable with a diameter of 12.50-20.90 mm |
|
PKV MK 362821 Exd-STARTER-M-12RT Explosion-proof starter - 12 A with a thermal relay, reverse, local control, 2 cable glands KV M20B-L for armored cable with a diameter of 12.50-20.90 mm |
|
PKV MK 362821 Exd-STARTER-D-12RT Explosion-proof starter - 12 A with a thermal relay, reverse, remote control, 3 cable glands KV M20B-L for armored cable with a diameter of 12.50-20.90 mm |
|
PKV MK 302021 Exd-STARTER-M-18 Explosion-proof starter - 18 A without thermal relay, local control, 2 cable glands KV M20B-L for armored cable with a diameter of 12.50-20.90 mm |
|
PKV MK 302021 Exd-STARTER-D-18 Explosion-proof starter - 18 A without thermal relay, remote control, 3 cable glands KV M20B-L for armored cable with a diameter of 12.50-20.90 mm |
|
PKV MK 302021 Exd-STARTER-M-18T Explosion-proof starter - 18 A with a thermal relay, local control, 2 cable glands KV M20B-L for armored cable with a diameter of 12.50-20.90 mm |
|
PKV MK 302021 Exd-STARTER-D-18T Explosion-proof starter - 18 A with a thermal relay, remote control, 3 cable glands KV M20B-L for armored cable with a diameter of 12.50-20.90 mm |
|
PKV MK 302021 Exd-STARTER-M-18R Explosion-proof starter - 18 A without thermal relay, reverse, local control, 2 cable glands KV M20B-L for armored cable with a diameter of 12.50-20.90 mm |
|
PKV MK 302021 Exd-STARTER-D-18R Explosion-proof starter - 18 A without thermal relay, reverse, remote control, 3 cable glands KV M20B-L for armored cable with a diameter of 12.50-20.90 mm |
|
PKV MK 362821 Exd-STARTER-M-18RT Explosion-proof starter - 18 A with a thermal relay, reverse, local control, 2 cable glands KV M20B-L for armored cable with a diameter of 12.50-20.90 mm |
|
PKV MK 362821 Exd-STARTER-D-18RT Explosion-proof starter - 18 A with a thermal relay, reverse, remote control, 3 cable glands KV M20B-L for armored cable with a diameter of 12.50-20.90 mm |
|
PKV MK 302021 Exd-STARTER-M-25 Explosion-proof starter - 25 A without thermal relay, local control, 2 cable glands KV M20B-L for armored cable with a diameter of 12.50-20.90 mm |