Annunciators of the Orbita MK M S series are designed to give disturbing light signals in fire and security alarm systems, as well as to indicate equipment operation modes and attract the attention of personnel in emergency situations.
Annunciators can be used with any fire and burglar alarm control panels.Type and level of protection 1 Ex db IIC T 6 Gb / Ex tb IIIC T 85 ° C Db, PB Ex db I Mb/ 1 Ex db IIC T6 Gb/Ex tb IIIC T85 °C Db according to GOST R IEC 60079-0-2011 .Annunciators can be used in hazardous areas and rooms of classes 1 and 2 in accordance with GOST IEC 60079-10-1-2011 and GOST IEC 60079-14-2011.
The sirens differ in supply voltage:
Distinctive features:
The posts are equipped with explosion-proof cable glands of the KV, KV series TU 27.33.13-138-81888935-2019.Connecting thread of cable glands M20x1.5.Cable glands allow you to enter and exit a round cable of various diameters
Alert | Mode | Parameters | |
---|---|---|---|
light | 1 step | strobe - flashes; blink 1; flashing 2; flash 3; flashing 4; permanent; | 70 ms at 1.3Hz; frequency 0.5Hz; frequency 1Hz; frequency 2Hz; frequency 3Hz; constant burning; |
2 step | strobe - flashes; blink 1; flashing 2; flash 3; flashing 4 permanent; | 70 ms at 1.3Hz; frequency 0.5Hz; frequency 1Hz; frequency 2Hz; frequency 3Hz; constant burning; |
The operating mode is selected by the user independently using dip-switches.Single-stage or two-stage modes are available.The second stage is switched on automatically after a fixed time of 3 minutes, or by means of an external control voltage.The type of alarm signal is selected by the user independently for each stage using dip-switches.6 operating modes are possible: blinking with frequencies 0.5Hz, 1, 2, 3Hz; 70ms strobe flash at 1.3Hz; constant glow.In the "strobe" mode, the brightness is 2 times higher than the constant glow or flashing modes.
Designation system when ordering
ORBIT MK M | WITH - | A - | TO |
one | 2 | 3 | 4 |
Explosion protection marking | 1 Ex db IIC T6 Gb/Ex tb IIIC T85 °C Db, PB Ex db I Mb/ 1 Ex db IIC T6 Gb/Ex tb IIIC T85 °C Db |
Sheath protection degree | IP67 |
Climatic performance | UHL1 |
Operating temperature range | -60С<Ta<+70С |
Supply voltage | 10.5V - 27VDC; 220V AC |
Consumption current, no more | 0.6Adc; 0.07Aac |
operating modes (seetable 2) | single stage two-stage |
Light Alert Color | Red (default); Green; Yellow; Blue; White; |
Light source type | 9 high brightness crystal LED |
Light intensity, not less | 50 cd |
Housing material | Aluminium alloy; Stainless steel |
Overall dimensions (LxWxH), not more than: | 115x100x115 |
Weight, not more than: | 1.5kg |