The detectors are manufactured in two versions with an addressable expander IP 103-723.5 - A2 - AZIMUT MK-AM - A, IP 103-723.6 - A3 - AZIMUT MK-AM - A, IP 103-723.7 - B - AZIMUT MK-AM - A, IP 103-723.8 - C - AZIMUT MK-AM - A, IP 103-723.13 - A2 - AZIMUT MK-AM - N, IP 103-723.14 - A3 - AZIMUT MK-AM - N, IP 103-723.15 - B - AZIMUT MK-AM - N, IP 103-723.16 - C - AZIMUT MK-AM - N and without it (without address mark) IP 103-723.1 - A2 - AZIMUT MK - A, IP 103-723.2 - A3 - AZIMUT MK - A , IP 103-723.3 - V - AZIMUT MK - A, IP 103-723.4 - C - AZIMUT MK - A, IP 103-723.9 - A2 - AZIMUT MK - N, IP 103-723.10 - A3 - AZIMUT MK - N, IP 103-723.11 - V - AZIMUT MK - N, IP 103-723.12 - S - AZIMUT MK - N and are used to detect a source of fire and transmit a signal to a control panel and is designed to work as part of automatic fire extinguishing systems and fire alarm systems as at objects special purpose (tanks with oil and oil products), and indoors.

The detector is a detector of maximum action and can be used in alarm loops for opening (series connection). The response temperature is set using the installed temperature switch. The current during operation (in the "FIRE" mode) is set by a resistor. The detector complies with TR EAEU 043/2017, TR CU 012/2011, GOST 31610.0-2014 (IEC 60079-0:2011), GOST 60079-1-2013, GOST 60079-31-2013, GOST 31439-2011 (EN 1710:2005 ), GOST R 53325-2012.

The detector is produced with address expander "S2000-AP1 version 2" manufactured by OOO "Bolid". The address version of the detector is used with the two-wire communication line controller "S2000-KDL" or "S2000-KDL-2I" as part of the integrated security system "Orion". https://bolid.ru/

The detector can be manufactured in two modifications: with a single sensor and with dual sensors. The dual version uses 2 sensors set to the same temperature. Modification with two sensors is used if it is necessary to reserve the failure of one of the sensors.

NameIP103 Azimuth MK
Explosion protection marking
Aluminium alloy1Ex db IIC T6…T5 Ga X / Ex tb IIIC T85°C…T100°C Db X
0Ex ia IIC T6… T5 Ga X / Ex ia IIIC T85°С… T100°С Db X (when connected to an external intrinsically safe circuit)
Stainless steelPB Ex db I Mb X / 1Ex db IIC T6…T5 Ga X / Ex tb IIIC T85°C…T100°C Db X
РO Ex ia I Ma X / 0Ex ia IIC T6… T5 Ga X / Ex ia IIIC T85°С … T100°С Db X (when connected to an external intrinsically safe circuit)
Degree of protection of the shellIP67
Operating temperature range, °C-60...+100
Rated DC or AC supply voltage of the passive detectorfrom 3V to 30V
Rated DC or AC switching currentfrom 0.1mA to 50mA
Maximum thermal relay currentno more than 100 mA
Contact circuit impedance with closed contactsno more than 1.0 Ohm
Overall dimensions, mmexcluding cable glands - 113x1000x162;
According to GOST 53325-2012Nominal response temperature set by the manufacturer
ClassTemperature, CTemperature ±5%, С
A254 - 7060
A364 - 7670
IN69 - 8580
C84 - 10090

Designation when ordering:

IP 103-723.14 - A3 - AZIMUT MK-AM - N1XTV1/2MR
1234

2 – sensor configuration:
1X - single sensor;
2X - dual sensor;

3 - type of cable entry:
K - for open cable laying with a diameter of 6.5-13.9 mm;
TV1 / 2 (TV20) - for laying a cable with a diameter of 6.5-13.9 mm in a pipe with a connecting internal thread G1 / 2 or M20x1.5;
ТН1/2 (ТН20) - for laying a cable with a diameter of 6.5-13.9 mm in a pipe with a connecting external thread G1/2 or M20x1.5;
B - for laying with double sealing of an armored cable with an outer part with a diameter of 15.0-21.0 mm and an inner sheath diameter of 6.5-13.9 mm;
KM10 - for laying a cable with a diameter of 3.1-8.6 mm in the RZTsH-10 metal hose;
KM12 - for laying a cable with a diameter of 3.1-8.6 mm in the RZTsH-12 metal hose;
KM15 - for laying a cable with a diameter of 6.1-11.7 mm in the RZTsH-15 metal hose;
KM20 - for laying a cable with a diameter of 6.5-13.9 mm in the RZTsH-20 metal hose;

4 - compliance with requirements and production under supervision:
MR - Maritime Register;
RR - River Register.