The detector is designed to detect fires accompanied by the appearance of electromagnetic radiation in the ultraviolet spectral range and to send a "Fire" notification to the control panel.The use of the UV part of the spectrum eliminates false alarms of the detector.The detector meets the requirements of GOST R 53325-2012.The detector is used in installations for fire protection of buildings, structures, premises and equipment in open areas.
The list of typical production premises, technological processes, for the protection of which the product is used:
The detectors are produced in versions differing in: type of explosion protection; body material; the presence of an address label (see.(see table 1 in the "Characteristics" tab).Explosion protection types: "flameproof enclosure" d "" and "intrinsically safe electrical circuit" ia "". Explosion protection marking, respectively: 1Ex d IIC T6 Gb X / Ex tb IIIC T85 ° C Db X and 0Ex ia IIC T6 Ga X / Ex ia IIIC T85 ° C Da X according to GOST R IEC 60079-0-2011.The "X" mark in the marking means: do not expose the light-transmitting part to mechanical stress.Body material: aluminum alloy; Cink Steel; stainless steel.
For the version "intrinsically safe electrical circuit" ia "" marking of explosion protection parameters: "Li: 1mkHn, Ci: 1000pF, Ui: 28B, Ii: 70mA, Pi: 2W" according to GOST R IEC 60079-11-2011.
The detectors in the version with the address label can be used with the controller of the two-wire communication line "S2000-KDL" or "S2000-KDL-2I" as part of the integrated security system "Orion".Detailed information on the use of address expanders and the use of the Orion integrated security system can be found on the manufacturer's website bolid.ru.
The detector is designed for operation at ambient temperatures from minus 60 ° С to plus 75 ° С, type of climatic modification UHL1 in accordance with GOST 15150-69.The degree of protection of the shell is IP67 in accordance with GOST 14254.Placement category 1 according to GOST 15150-69.
Table 1.
Designation | Body material | Explosion protection type |
IP329-310.1-1 Telos MK-S (-AM) | Cink Steel | PB Ex d I Mb X / 1Ex d IIС T6 Gb X / Ex tb IIIC T85 ° C Db X |
IP329-310.1-1 Telos MK-N (-AM) | Stainless steel | PB Ex d I Mb X / 1Ex d IIС T6 Gb X / Ex tb IIIC T85 ° C Db X |
IP329-310-1 Telos VZ-N (-AM) | Stainless steel | PO Ex ia I Ma X / 0Ex ia IIC T6 Ga X / Ex ia IIIC T85 ° C Da X |
IP329-310.1-1 Telos MK-A (-AM) | Aluminium alloy | PB Ex d I Mb X / 1Ex d IIС T6 Gb X / Ex tb IIIC T85 ° C Db X |
IP329-310-1 Telos VZ-A (-AM) | Aluminium alloy | PO Ex ia I Ma X / 0Ex ia IIC T6 Ga X / Ex ia IIIC T85 ° C Da X |
Table 2.
Characteristic | Meaning | |
Spectral sensitivity, nm | Uv | 185 - 260 |
Detection range of test foci, m, not less | TP-5 (N-heptane) | 25 |
TP-6 (ethyl alcohol) | 25 | |
Viewing angle, gr | Uv | 90 |
Response time, sec | Uv | 4 |
Direct light resistance, not less lux | incandescent lamps | 250 |
fluorescent lamps | 2500 | |
Resistance to optical radiation in the visible range of the spectrum, no more, lux | 80,000 | |
Supply voltage, V | 8 - 28 | |
Consumption current, no more, mA | without heating | twenty |
heated | 350 | |
Characteristics of the Sh1 and Sh2 optocoupler relays | maximum voltage, V, not more | 100 |
maximum current, mA, not more | 100 | |
open resistance, Ohm, no more | 16 | |
isolation voltage, V, not less | 1500 | |
Address label interface | DPLS v2.xx "Orion" | |
Ready time after power supply, no more, sec | 45 | |
Diameter of the cable to be inserted, mm | 8 - 12 | |
Section of the connected conductors, mm 2 | 0.35 - 1.5 | |
Operating temperature range, ° С | -60 - +75 | |
Sheath protection | IP67 | |
Climatic performance | UHL1 | |
Overall dimensions, mm | 334x271x116 | |
Weight, no more, kg | 3.5kg |
AM - indicates the presence of a modification of the product with an address label. An example of a detector designation when ordering:
IP329-310.1-1 Telos | - MK - | WITH | - AM - | Kv |
1 | 2 | 3 | 4 | 5 |
Downloads: